Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 33(3): 403-407, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28302987

RESUMO

A certified reference material (CRM), NMIJ CRM 7203-a, was developed for the elemental analysis of tap water. At least two independent analytical methods were applied to characterize the certified value of each element. The elements certified in the present CRM were as follows: Al, As, B, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Sb, Se, Sr, and Zn. The certified value for each element was given as the (property value ± expanded uncertainty), with a coverage factor of 2 for the expanded uncertainty. The expanded uncertainties were estimated while considering the contribution of the analytical methods, the method-to-method variance, the sample homogeneity, the long-term stability, and the concentrations of the standard solutions for calibration. The concentration of Hg (0.39 µg kg-1) was given as the information value, since loss of Hg was observed when the sample was stored at room temperature and exposed to light. The certified values of selected elements were confirmed by a co-analysis carried out independently by the NMIJ (Japan) and the KRISS (Korea).


Assuntos
Água Potável/análise , Oligoelementos/análise , Água Potável/normas , Japão , Espectrometria de Massas/normas , Padrões de Referência , República da Coreia , Oligoelementos/normas
2.
Anal Bioanal Chem ; 401(9): 2909-18, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21928079

RESUMO

The National Metrology Institute of Japan has issued a certified reference material of tunnel dust for polycyclic aromatic hydrocarbons (PAHs) and toxic element analyses. PAH certification was performed using isotope dilution mass spectrometry with deuterium-labeled PAHs as internal standards. Three extraction techniques (microwave-assisted extraction with toluene/methanol, Soxhlet extraction with toluene, and pressurized liquid extraction with toluene) were used, and the extracts were measured by gas chromatography/mass spectrometry with two different columns. For values of PAHs, 11 PAHs are provided as certified values between 0.294 and 20.3 mg/kg, and five PAHs are provided as information values. Certified values of five toxic elements (Cr, Ni, Pb, Mn, and Cd) obtained from microwave-assisted digestions and a combination of measurement techniques are also provided between 43.4 and 10.71 × 10(3) mg/kg.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...